Skip Navigation
Small Business Innovation Research/Small Business Tech Transfer

Very large computer generated holograms for precision metrology of aspheric optical surfaces

Completed Technology Project
393 views

Project Description

Very large computer generated holograms for precision metrology of aspheric optical surfaces
Both ground and space telescopes employ aspheric mirrors. A particular example is the X-ray telescope where primary and secondary mirrors have nearly cylindrical surfaces. Computer Generated Holograms (CGH), in combination with commercial interferometers, provide high resolution and high accuracy measurements of aspheric optical surfaces. The current state of the art CGHs are made on 6" square substrates such as those for testing the primary segments of James Webb Space Telescope. However, larger CGHs are always desired. A larger CGH enables testing of correspondingly larger convex and nearly cylindrical concave surfaces in one shot; studies have shown that larger CGHs also offer better imaging of the surface under test, which improves the CGH null test system's Instrument Transfer Function, an equivalent metric to an imaging system's Modulation Transfer Function. Furthermore, pursuit of improving CGH test accuracy never ends. The fundamental limiting factor is quality of the substrate. The current state of the art technology is still unable to fabricate general CGHs of arbitrary symmetry on high quality custom substrates. Arizona Optical Metrology LLC (AOM) proposes to address these problems. We propose to work with our collaborators at the ebeam facility of Jet Propulsion Laboratory of NASA to write large CGHs on high quality substrates. We anticipate the writing has reasonable yet non-negligible errors which cause errors in the aspheric wavefront the CGH produces. The wavefront error must be calibrated in order to meet the demanding accuracy requirement of precision aspheric surface metrology. We propose to develop a technology that enables accurate calibration of the writing error, such that the CGH still measures an aspheric surface to an excellent accuracy of a couple of nm rms. The goal of phase 1 is to develop the software tools for calibrating the CGH writing error, and fabricate a couple of 9 inch diameter CGHs to experimentally validate the technology. More »

Anticipated Benefits

Primary U.S. Work Locations and Key Partners

Technology Transitions

Light bulb

Suggest an Edit

Recommend changes and additions to this project record.

This is a historic project that was completed before the creation of TechPort on October 1, 2012. Available data has been included. This record may contain less data than currently active projects.

^